For integrated surveying services ECPS offers all types of Electric Cables either mono conductor or multi-conductor and high temperature electric cables.
Structure:
- Copper Conductor: 19×0.37 mm 19×0.0146〃
- PFA Insulation: 3.81mm 0.1496〃
- Inner Armor Layer: 12×1.15mm(1808N) 12×0.0437〃(406lbs)
- Outer Armor layer: 18×1.15mm(1808N) 18×0.0437〃(406lbs)
Physical Property:
- Cable Diameter: 8.00mm±0.10mm 0.315″±0.0039″
- Cable Weight in Air: 281 kg/km 189 lbs/kft
- Temperature Rating: 260 ℃ 500 ℉
Mechanical Property:
- Cable Breaking Strength: 45 kN 10000 lbs
- Minimum Sheave Diameter: 450 mm 18″
- Cable Stretch Coefficient: 1.35 m/km/5kN 1.2 ft/kft/klbs
Electrical Property:
- Voltage Rating: 1500 VDC 1500 VDC
- Insulation Resistance: 15000 MΩ/km 50000 MΩ/kft
- D.C.Resistance in 20℃: 9.2 Ω/km 2.8 Ω/kf
- Capacitance @ 1 kHz: 190 pf/m 58 pf/kft
|
 |